CNG TROLLEY TR35-84

SUPREME CORPORATION Pdf Download PDF Report

Fuel Economy Data (Gaseous Fuels)

Date: 2001-11-28
Run Number: 1
Personnel: S.C., T.S. & B.S.
Test Direction: CCW
Ambient Temperature (°F): 48
Humidity (%): 81
SLW (lbs): 26450
Wind Speed (mpg) & Direction: /Calm
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:47 8:47 50.4 46.0
ART #1 0 3:58 3:58 41.6 53.8
CBD #2 0 8:30 8:30 44.5 42.6
Art #2 0 4:01 4:01 32.2 54.5
CBD #3 0 8:38 8:38 35.6 45.7
Commuter 0 6:00 6:00 48.2 68.9
Total Fuel: 311.5 SCF
20 minute idle: 0.0 SCF
No Load Flow Rate at Idle = 0.0 SCFM No Load Flow Rate at Full Throttle = 8.75 SCFM
Heating Value = 1008.1 BTU/LB
Comments: Test vehicle idles on diesel fuel only.

Date: 2001-11-28
Run Number: 2
Personnel: S.C., T.D., & B.S.
Test Direction: CW
Ambient Temperature (°F): 52
Humidity (%): 81
SLW (lbs): 26450
Wind Speed (mpg) & Direction: /Calm
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:23 8:23 67.5 46.7
ART #1 0 4:08 4:08 65.3 52.8
CBD #2 0 8:48 8:48 63.3 47.0
Art #2 0 4:05 4:05 58.0 53.1
CBD #3 0 8:50 8:50 48.5 58.9
Commuter 0 6:06 6:06 42.3 71.1
Total Fuel: 329.6 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: None.

Date: 2001-11-28
Run Number: 3
Personnel: S.C., T.S. & B.S.
Test Direction: CCW
Ambient Temperature (°F): 45
Humidity (%): 82
SLW (lbs): 26450
Wind Speed (mpg) & Direction: 6/WSW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:52 8:52 49.9 45.0
ART #1 0 4:08 4:08 44.3 59.5
CBD #2 0 8:48 8:48 48.7 46.8
Art #2 0 4:06 4:06 42.3 60.1
CBD #3 0 8:43 8:43 43.0 45.3
Commuter 0 5:58 5:58 44.7 61.8
Total Fuel: 318.5 SCF
20 minute idle: SCF
No Load Flow Rate at Idle = SCFM No Load Flow Rate at Full Throttle = SCFM
Heating Value = 1008.1 BTU/LB
Comments: None

Date: 2001-11-29
Run Number: 4
Personnel: S.C., T.S. & B.S.
Test Direction: CW
Ambient Temperature (°F): 54
Humidity (%): 82
SLW (lbs): 26450
Wind Speed (mpg) & Direction: 6/WSW
Barometric Pressure (in.Hg): 30
Cycle Type Run Time (min:sec) Cycle Time
(min:sec)
Fuel Temperature (°F) Total Fuel used (SCF)
Start Finish Start
CBD #1 0 8:49 8:49 55.9 43.3
ART #1 0 4:13 4:13 50.1 49.5
CBD #2 0 8:46 8:46 49.2 44.5
Art #2 0 4:07 4:07 52.0 50.0
CBD #3 0 8:49 8:49 51.8 44.3
Commuter 0 6:05 6:05 49.8 60.4
Total Fuel: 292.0 SCF
20 minute idle: 0.0 SCF
No Load Flow Rate at Idle = 0.0 SCFM No Load Flow Rate at Full Throttle = 12.45 SCFM
Heating Value = 1008.1 BTU/LB
Comments: None.