CNG TROLLEY TR35-84

SUPREME CORPORATION Pdf Download PDF Report

Exterior Noise Test

Accelerating from Constant Speed

Date : 2001-12-03
Personnel : S.C., E.D. & B.S.
Temperature (°F) : 40 Humidity (%) : 80
Wind Speed (mph) : 5 Wind Direction : SSW
Barometric Pressure (in.Hg) : 30.3
Verify that microphone height is 4 feet, wind speed is less than 12 mpg and ambient temperature is between 30 F and 90 F: true checked by S.C.
Initial Sound Level Meter Calibration: false checked by S.C.
Exterior Ambient Noise Level dB(A): 40.3

Accelerating from Constant Speed
Curb (Right) Side
Accelerating from Constant Speed
Street (Left) Side
Run # Measured Noise Level dB(A) Run # Measured Noise Level dB(A)
1 83.6 1 83.5
2 84.2 2 83.5
3 84.5 3 82.5
4 84.5 4 83.8
5 84.3 5 84.3
Average of two highest actual noise levels = 84.5 dB(A) Average of two highest actual noise levels = 84.1 dB(A)