ULTRA LF

BLUE BIRD CORPORATION Pdf Download PDF Report

Static Towing Test Data Form

Date: 2005-04-21
Personnel: T.S. & S.C.
Temperature: 62

 

Inspect right front tow eye and adjoining structure.
Comments: Welds inspected and verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation observed.
Inspect left front tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
Inspect right rear tow eye and adjoining structure.
Comments: Welds inspected and verified.
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: No damage or deformation observed.
Inspect left rear tow eye and adjoining structure.
Comments: N/A
Check the torque of all bolts attaching tow eye and surrounding structure.
Comments: N/A
General comments of any other structure deformation or failure:
Load interface was accomplished by removing the front bumper. The full test load of 26,592 lbs (1.2 x 22,160 lbs C.W.) was acquired with no damage or deformation observed.